2500 W power and 40 A charging current. Balancing current 2 A. Balancing power 100 W!
All types of rechargeable batteries can be charged with 40 A (even with maximum cell count) without restriction. Short circuit and polarity protected!
The Pulsar 3+ charger is a further development of the Pulsar 3. The charging and balancing performance has been increased again. Also, the possible sources of error in the operation were excluded once and for all. The Pulsar 3+ has a completely redesigned balancer conception, which does not cause any damage to the balancing connectors. Also the increased balancer performance (by the use of appropriate plugs and connection wires) allows balancing with currents of up to 2 A per cell, with an enormous balancer total output of 100 W. The Pulsar 3+ charger has qualities which make a big difference to products of other manufacturers. Most of them are features which were too expensive or even too complicated for our competitors. We went through a long development time and did not like to have any technical compromises which could lower the functionality of our unrivalled charger. The developers could realize a very high accuracy and stability of all parameters at the full power spectrum of this device, also for functions like impulse or reflex. Other chargers lose a lot of time while CCV stage of charging LiXX batteries, but the Pulsar 3 uses the genuine FASTMOD function (used in Pulsar 2, Pulsar 2+ and Pulsar 3) to shorten charging time rigorous (up to 30 % faster compared to standard charging mode). At the same time, the FASTMOD method is very gentle for your battery packs. The balancer for 16 cells has enough power also for future battery packs with more capacity. It uses continuous current instead of discharge impulse and is able to balance 16 cells at the same time, even with different currents. The intuitive one-button control, a big graphical display, logging of all processes on SD card, optional BT or BT/WiFi communication, different setups for usage on car battery or power supply - these are just a few features that confirm this well-engineered Pulsar 3 charger. As the developers are not satisfied by using standard PC software, they made a special software for this charger and include it in the scope of delivery. Features :
Separate setup parameters for usage with car battery and power supply
Storage program for charging/discharging to storage voltage
Cycles (up to 99): charge/discharge; discharge/charge (current can be set up differently between charge and discharge) and format
Format with battery regeneration function (NiXX)
Permanent measurement of internal resistance (Ri) while charging (only impulse mode)
Built-in balancer for up to 16 cells (simultaneous balancing up to 16 cells)
Max. balancing current 2 A/cell (pre-setup in 4 steps: 0,0 A = no balancing - only display; 0,5 A; 1,0 A; 2,0 A)
Balancing only mode (whole voltage range)
Balancing power 100 W
Balancing current - automatically variable individually in 10 steps per cell
Intelligent balancing algorithm
Balancing start voltage automatically ascertainable - depends on height of cell debalancing
Balancing funnel-shaped - full cells means more intense balancing
Process memory (last processes data): 20
Program memory (user settings): 20
Charging finish identification (NiXX): Delta-peak (adjustable from 1 to 25 mV in steps of 0,5 mV); Inflex; charging time; adjusted capacity
Pb, Li-Ion, LiPo, LiHV, LiFe - finish voltage of charging +100 / - 200 mV adjustable
Fastmod (genuine) for Li-Ion, LiPo, LiHV, LiFe, Pb
Reflex function - (memory effect protection for NiCd & NiMH), lowers voltage drift at LiXX
Modes: Impulse, Reflex, adjusted for usage with power supply (Impulse mode off)
If not used, zero voltage at output (safety for charging batteries inside of devices, e.g. transmitter)
Reverse battery protection (input, output)
Anti-spark circuit for battery and supply of current
Charger housing isolated from earth (minus); no short circuit at housing possible
Temperature sensor
Step-down/step-up converter for full charging of single cell batteries
Discharge process up to 100 W with external mains power supply without additional, external resistors
Reverse - returns discharging current to supply battery starting from 4 V
Protects supply battery against overcharging (in reverse mode)
Adjustable min. voltage of supply battery 10,5 - 11,5 V (protects against deep discharge) 10,0-11,5 V (also 24 V, 36 V and 48 V)
Digital control converter with special digital signal processor (DSP: allows fast and precise control)
Graphical display 240 x 64 pixel
Permanent display backlight (brightness and contrast adjustable); reverse display possible (negative)
Acoustic alarm (disengageable)
Individual configuration on SD card (possible temporary use in other devices)
Process logging on SD card (archive and analysis on PC possible)
Built-in real-time clock (time will be also logged to SD card)
USB connection (cable included)
Optional BT or BT/WiFi communication class 1 (up to 100 m range) with external antenna for communication with PC and smartphones
Automatic time (clock) synchronization with PC, notebook, tablet or smartphone
Internal cooling fan with smooth adjusting (very quiet - only one fan)
PC Software (bundled with charger)
SD card included
Free upgrades via internet
Small size (no external radiator) 155 x 160 x 75 mm, weight 1.850 g
Scope of delivery
Charger Pulsar 3+
Instruction manual
Balancing adaptor
Adaptor cable for standard charging cables
Connection cable with crocodile clamps
SD-card
USB-cable
Optional: BT antenna (only if BT or BT / WLAN module is installed)
Warnhinweise
http://www.pp-rc.de.pprc.kasserver.com/SHOP/FOTO/PULSAR_DOWNLOAD/PULSAR3P/Instr_Pulsar3Plus_de.pdf
http://www.pp-rc.de.pprc.kasserver.com/SHOP/FOTO/PULSAR3/Instr_Pulsar_BT_de_en.pdf
http://www.pp-rc.de.pprc.kasserver.com/SHOP/FOTO/PULSAR3/Instr_Pulsar_BT_WLAN_de_en.pdf
http://www.pp-rc.de.pprc.kasserver.com/SHOP/FOTO/PULSAR3P/Garantiebedingungen_ELPROG.pdf
http://www.pp-rc.de.dd29924.kasserver.com/SHOP/FOTO/PULSAR3/Instr_Pulsar3_en.pdf
Bestimmungsgemäßer Gebrauch
Der Pulsar 3+ ist ein Akkuladegerät mit integriertem Balancer und optimiert für das Laden, Entladen, Testen sowie die Pflege von Akkupacks, die im RC-Modellsport eingesetzt werden. Das Laden von Bleibatterien ist möglich, aber das Ladegerät ist für Blei-Gel-Akkus optimiert. Eine Benutzung für andere Zwecke (z. B. für Akkupacks von Elektrofahrädern u. ä.) ist möglich, setzt aber gewisse technische Vorkenntnisse voraus. Eine unsachgemäße Verwendung kann unter Umständen zu Beschädigungen bzw. Folgeschäden führen und sogar eine Gefahr für die Gesundheit darstellen. Daher ist der Gebrauch auf den vorgesehenen Zweck zu begrenzen.
EG-Konformitätserklärung
Wir erklären hiermit die Übereinstimmung des Pulsar 3+ mit den allgemeinen Anforderungen für die Sicherheit– insbesondere in Bezug auf Schutz der Gesundheit – des Benutzers und anderer Personen nach der Richtlinie 2014/35/EU und die in der Richtlinie 2014/30/EU enthaltenen Schutzanforderungen in Bezug auf die elektromagnetische Verträglichkeit. Das Produkt erfüllt folgende Normen (Elektromagnetische Verträglichkeit - Anforderungen an Haushaltgeräte, Elektrowerkzeuge und ähnliche Elektrogeräte - Teil 1: Störaussendung): DIN EN 55014-1:2016-09; (Teil 2: Störfestigkeit) DIN EN 55014-2:201-01
Das Gerät ist gekennzeichnet mit: Am Ende der Lebensdauer als ELPROG Elektronikschrott entsorgen! ul. PrzemysÅ‚owa 11 35-105 Rzeszów Polen
Alleiniger Vertrieb:
pp-rc Modellbau Piechowski Tel: +494121 740486
Paul-Junge-Str. 10 Fax: +49 4121 750676
25336 Elmshorn
www.pp-rc.de
GERMANY WEEE-Reg.-Nr DE77074747
Begriffe, Abkürzungen und Symbole(alphabetisch aufgelistet) Zellentypen:
NiXX = NiCd (Nickel-Cadmium),NiMH (Nickel-Metallhydrid), NiZn (Nickel-Zink)
LiXX = LiPo (Lithium-Polymer), LiIon (Lithium-Ionen), LiFe, LiHV (Lithium Hochvolt)
Pb = Bleibatterie (auch Blei-Gel-Batterie)
Funktionen:
Charge = Laden
Ch.Dis = Laden – Entladen (Doppelprozess)
Condit = Laden - Entladen (Kapazitätsermittlung) - Laden auf Lagerungsspannung
Disch. = Entladen
Dis.Ch. = Entladen – Laden (Doppelprozess)
Format = Spezielles Programm, um die NiXX-Akkus zu formieren
Store = Spezielles Programm, um die Akkupacks auf die Lagerungsspannung zu bringen (je nach Spannungslage, das Akku wird automatisch entladen oder geladen). Nur bei LiXX-Akkus verfügbar.
Test = Spezielles Programm, um den Innenwiderstand der Akkus zu bestimmen (Test durch Entladeimpulse)
Parameter und Abkürzungen:
↑ = Spannungsanstieg: Wird über dem „V“ (Volt) beim Laden oder Entladen angezeigt. Der Pfeil wird auch im Balancierungsfenster als Anzeige für die Zelle mit der höchsten Spannung verwendet. ↓ = Spannungsabfall: Wird über dem „V“ (Volt) beim Laden oder Entladen angezeigt. Der Pfeil wird auch im Balancierungsfenster als Anzeige für die Zelle mit der niedrigsten Spannung verwendet. Δ(bei NiCd und NiMH) = Wert des Delta-Peaks: Lade-Voll-Erkennung der NiXX-Zellen Δ(bei LiXX) = Spannungsdifferenz bei LiXX-Zellen (in Balancermenü) -,- Ah = Einstellungen des Kapazitäts-Limiters ! = Ausrufezeichen markiert den zu Werkseinstellungen verstellten Wert der Parameter (z. B. geänderte Lade-Endspannung). Ausrufezeichen über Amperzahl (A) bedeutet, dass Lade- oder Entladestrom wegen Leistungsbegrenzung nicht erreicht werden kann. Ah/c (ampere-hour / cell) = Ausgeglichene Kapazität (im Balancermenü) Auto = Automatische Stromreduzierung beim Entladen (Entladestrom wird mehrmals reduziert, um eine tiefere Entladung zu erreichen) B: (Balancer) = Momentane Balancerleistung B ("B" blinkt abwechselnd mit „V“) = zusätzliche Nachbalancierung (falls der Akkupack beim Ende des Ladens noch nicht vollständig ausbalanciert ist) Beep = Beeper – akustischer Signalgeber BT = Optionale BT-Funkkommunikation C (capacity) = Geladene oder entladene Kapazität c (Laderate) = auf die Kapazität des Akkus in Ah bezogener Lade- oder Entladestrom. Wenn der Limiter aktiv ist, dann wird bei der Stromeinstellung zusätzlich die C-Laderate angezeigt Config (0-9) = Speicherung (und Auslesen) der aktuellen Konfigurationen (inkl. Memory) auf der SD-Karte Contr. (contrast) = Kontrast des Displays Cs (capacity supplied) = Die für das Laden entnommen Kapazität am Eingang (ermöglicht Einschätzen der verbleibenden Energie der Autobatterie). Der Cs-Wert kann wahlweise manuell bzw. automatisch über Datumswechsel genullt werden. Die entsprechende Einstellung wird im „SD,RF,RTC“-Menü vorgenommen. Ein langer Druck auf den Bedienungsknopf der Cs-Wert auf null gesetzt. E (end) = blinkt abwechselnd mit „V“ wenn die Stromreduktion am Ende des Prozesses (Laden oder Entladen) begonnen hat. Fast = Fastmod – Schnellladefunktion bei LiXX und NiZN-Zellen I = Inflex-Erkennung („I“ blinkt abwechselnd mit „V“) Ib = Balancer-Ausgleichsstrom (0 = nur Anzeige, ohne dass der Balancer aktiv wird) Inflex = Akku schonende Lade-Voll-Erkennung der NiXX-Zellen Invers = Negativdarstellung des Displays Last proc. = Daten des letzten Prozesses Light = Helligkeit des Displays mΩ/c = Innenwiderstand (in mΩ) pro Zelle M (memory)= Speicherplatznummer Monitor = Anzeige der Zellenspannungen über Balancereingang (ohne zu balancieren - "only Bal") P (pulse)= Wird abwechselnd mit „V“ (Volt) beim Laden im Fastmod angezeigt; signalisiert am Ende des Prozesses, dass die Pausen zwischen den Ladeimpulsen verlängert werden Pause = Pause in Sekunden zwischen den Prozessen (z. B. beim Laden – Entladen) Power = Eingangsleistung (Leistung des Netzteils) kann für schwächere Netzteile oder kleinere Autobatterien reduziert werden. Pulse = Impulsbetrieb (nur abzuschalten für den Betrieb an Netzteilen mit Stromaggregaten, die empfindlich auf Stromschwankungen reagieren) R (Reverse) / V (Volt) = signalisiert beim Entladen mit Energierückführung durch abwechselndes Blinken die Stromreduzierung (die Spannung „Vrev“ wurde überschritten) R (Stromreduktion) = wird hinter dem Spannungswert im Prozessfenster angezeigt, wenn durch die zu niedrigeSpannung des Versorgungsakkus die Leistung reduziert wurde.Reflex = Das Impulsladen wird mit einem kurzen Entladeimpuls ergänzt. Am besten bei allen Zellentypen eingeschaltet lassen! Regen. = Regenerierungsfunktion – zuschaltbar beim Formieren Rep.*99 (repeat) = Wiederholung der Doppelprozesse (Zyklen oder Formierung) Revers = Energierückführung zur Autobatterie beim Entladen (ermöglicht eine höhere Entladeleistung) RF = radio frequency – Kommunikation über BT oder WiFi (WLAN) Ri = Innenwiderstand des Akkupacks in ΩRTC (real time clock) = Echtzeituhr – wichtig für die Datenspeicherung auf SD-Speicherkarte SD = Secure Digital Memory Card – Speicherkarte für die Prozesse und Einstellungen Sup. (supply) = Stromversorgung – im Setup können Netzteil oder Akkutyp und Zellenzahl ausgewählt werden. Tc = Temperatur (gemessen mit dem beigefügten Temperaturfühler) Ti = Gerätetemperatur (Alarme) T off = Maximale Temperatur, bei der der Prozess unterbrochen wird (gemessen über Temperaturfühler) T on = Temperatur, bei der der Prozess gestartet wird V/c (Volt / cell) = Spannung der einzelnen Zellen (nur bei den Balancerfunktionen) Vc (Volt charge) = Ladeschlussspannung (kann verändert werden) Vd (Volt discharge) = Entladeschlussspannung (kann verändert werden) 6 Ve (Volt end) = Lagerungsspannung (Store) V off = Minimale Spannung der Stromversorgung, bei der der Prozess beendet wird (schont die Autobatterie) Vrev (Volt Reverse) = Maximale Spannung der Versorgungsbatterie überschritten (Überschreitung der Spannung bewirkt Reduzierung des Entladestroms)Vs (Volt supplied) = Eingangsspannung (Autobatterie oder Netzteil)
RC models are no toys. For children under 14 years of age onlly under adult supervision.
Dieser Shop wurde vollständing mit hbso.deShop-Solution implementiertAlle Rechte vorbehaltenAlle Preise inkl. MwSt. zzgl. Versandkosten
Shopsystem u. Shopsoftware von hbso.de